some equallogic info
the remote setup wizard application requires two ethernet ports to be located on the same switch within the same vlan (fairly obvious). also the nic that is initially configured is eth0 on the active controller.
when adding a new member array to a pre-existing group it’s best to upgrade the firmware on all members within the group prior. once the new member is added then upgrade its firmware (if necessary) to match the group’s version.
serial connection:
9600 baud
8-n-1
no flow control
generate a diagnostic report:
ssh into an interface on the appropriate member and run the diag command. the diagnostic wizard will begin.
misc info:
after ssh-ing into the equallogic group management the following commands can be ran to gain some information:
member select member_name show
or
member select member_name show component_name
some component names include:
controllers, disks or disks #, eths or eth #, version, volumes
source:
http://psonlinehelp.equallogic.com/V3.3/member_select_show_.htm